What Should You Always Do When Using A Micropipette?

Advertisements
  1. Select the volume.
  2. Set the tip.
  3. Press and hold the plunger at the first stop.
  4. Place the tip in the liquid.
  5. Slowly release the plunger.
  6. Pause for a second and then move the tip.
  7. Insert the tip into the delivery vessel.
  8. Press the plunger to the second stop.

What are the dos and don’ts when using a micropipette?

Do not attached tip by hands, even with gloves. 2- Do not turn the pippete on its side when there is liquid in the tip. 3-Do not clean tips for REUSE, as their metrological characteristics will no longer be reliable. 4- Don’t contaminate you or the pipette.

How precise is a micropipette?

When micropipettes are calibrated, the accuracy is normally expressed as a percent of the selected value. Micropipettes are designed to operate with accuracies within a few percent (generally <3%) of the intended value.

What are three important precautions in micropipette use?

Take the following precautions when using a micropipette:

run back into the piston. ➢ NEVER let the plunger snap back after withdrawing or expelling fluid; this could damage the piston. ➢ NEVER immerse the barrel of the micropipettor in fluid. ➢ NEVER flame the tip of the micropipettor.

What can damage a micropipette?

10 Ways to Abuse a Pipette

  • Forgetting your head. When using a pipette, always use a tip. …
  • The wrong guy for the job. Make sure your tip is the right one for the volume you are pipetting. …
  • Pushing it too far. …
  • It’s a pipette, not a plunger. …
  • Leaving it lying around. …
  • Using it as a backscratcher. …
  • Holding it wrong. …
  • Dialing it up.

What are 5 safety precautions for a laboratory?

Basic Safety Rules

  • Know locations of laboratory safety showers, eyewashstations, and fire extinguishers. …
  • Know emergency exit routes.
  • Avoid skin and eye contact with all chemicals.
  • Minimize all chemical exposures.
  • No horseplay will be tolerated.
  • Assume that all chemicals of unknown toxicity are highly toxic.

Why is a micropipette accurate?

Manufacturers determine the accuracy and precision of micropipettes by using them to transfer defined volumes of distilled water to a drop that is then weighed on an analytical balance. … Accuracy is computed from the difference between the actual volume dispensed by the micropipette and the intended volume.

How precise is a burette?

10 mL burettes are usually graduated each 0.05 mL, while 25 mL and 50 mL burettes are usually graduated each 0.1 mL. That means that 50 mL burettes have the highest resolution. 0.050 mL out of 50 mL is 0.1%, and that’s about maximum precision that we can get from volume measurement when using burette.

Why should you avoid touching the micropipette tips?

Why should you avoid touching the micropipette tips? Too much immersion will cause liquid to stick to the outside of the tip, and too little immersion will result in air bubbles. Minimize handling of the pipette and tip – The heat transferred from your hands to the pipette and/or the tips can affect delivery volumes.

What should be avoided when using a micropipette?

The solution into which the micropipetted solution is to be placed is often called the “receiving liquid.” Do not allow the tip of your micropipette to touch the receiving liquid. Some of the liquid may be drawn back up into the micropipette, contaminating your sample for the remainder of the micropipette sequence.

When using a Micropipettor if you push to the second stop to fill it you will?

He says that pushing to the second stop messes up the vacuum and causes you to draw in more liquid the next time you use it. If you don’t change tips, it’s better to leave a little liquid in the tip.

Advertisements

Which micropipette is most accurate?

The volumetric pipette remains the world’s most accurate.

What is the largest source of pipetting problems?

Human error is the largest source of pipetting problems, followed by liquids sticking to the tips, and loss of accuracy when working with viscous liquids (multi-option select question, chart depicts the percent of survey respondents who experienced these various pipetting errors).

When using a Gilson micropipette What should you do first?

1. Press the push button to the first stop (this corresponds to the set volume of liquid). 2. Hold the pipette vertically and immerse the tip in the liquid (refer to Guidelines for Good Pipetting on page 9).

What are the different types of micropipettes?

Micropipettes are of two types, the Fixed micropipettes, and the Variable Micropipettes. The Fixed micropipettes are designed to transfer the fixed amount of volume of the liquid. The fixed micropipettes cannot be adjusted to withdraw more or less of the volume.

How can I improve my pipetting precision?

  1. Pre-wet the pipette tip. Aspirate and fully expel an amount of the liquid at least three times before aspirating for delivery. …
  2. Examine the pipette tip for droplets. …
  3. Pause consistently. …
  4. Minimize handling of pipette and tip. …
  5. Use the correct pipette tip.

Why are pipettes not accurate?

Temperature and pressure affect the volume of the air cushion, which affects pipetting accuracy. Also, volatile solvents can evaporate into the air cushion, which leads to an inaccurate and lower dispensed volume than that displayed on the pipette.

Why can’t you use the second stop to draw liquid up into the tip?

Never release the pipetting button from the second stop when the tip is immersed in liquid. This would draw up liquid beyond the maximum volume, which could be more volume than the tip can fit. In that case, the liquid could reach into the pipette itself, which can end up damaging it.

What are 10 safety rules?

10 Safety Rules Your Child Should Learn

  1. Rule #1: Know Your Name, Number, & Address. …
  2. Rule #2 Talking to Strangers is a Big No. …
  3. Rule #3 Good Touch & Bad Touch. …
  4. Rule #4 Never Climb a Wall or a Fence. …
  5. Rule #5 Playing with Fire & Sharp Objects Not Allowed. …
  6. Rule #6 Your Child Should be Aware of the School Emergency Procedures.

What are the 10 lab safety rules?

The 10 Most Important Lab Safety Rules

  • of 10. The Most Important Lab Safety Rule. …
  • of 10. Know the Location of Safety Equipment. …
  • of 10. Dress for the Lab. …
  • of 10. Don’t Eat or Drink in the Laboratory. …
  • of 10. Don’t Taste or Sniff Chemicals. …
  • of 10. Don’t Play Mad Scientist in the Laboratory. …
  • of 10. Dispose of Lab Waste Properly. …
  • of 10.

What is the most important laboratory safety rule?

1. Wear protective lab attire: Make sure you use PPE at all times inside the laboratory. Put on a lab coat with full sleeves, closed-toe shoes, and safety goggles before entering the lab. If you have long hair, it’s better to keep it tied and out of the way when working in the lab.

What happens if you release the micropipette plunger too fast?

What this means is that once the plunger returns to its original position, the liquid usually hasn’t finished moving into the tip. Therefore, if you remove the pipette tip from the liquid too quickly before dispensing, you can end up transferring less volume than you intended.

Advertisements